<!DOCTYPE FL_Course SYSTEM "https://www.flane.de/dtd/fl_course095.dtd"><?xml-stylesheet type="text/xsl" href="https://portal.flane.ch/css/xml-course.xsl"?><course productid="34797" language="fr" source="https://portal.flane.ch/swisscom/fr/xml-course/juniper-idcfev" lastchanged="2025-07-29T12:18:31+02:00" parent="https://portal.flane.ch/swisscom/fr/xml-courses"><title>Implementing Data Center Fabric with EVPN and VXLAN</title><productcode>IDCFEV</productcode><vendorcode>JP</vendorcode><vendorname>Juniper Networks</vendorname><fullproductcode>JP-IDCFEV</fullproductcode><version>1.0</version><objective>&lt;ul&gt;
&lt;li&gt;Describe basic and advanced data center design concepts.&lt;/li&gt;&lt;li&gt;Describe and configure an IP fabric.&lt;/li&gt;&lt;li&gt;Describe and configure an EVPN-VXLAN data center.&lt;/li&gt;&lt;li&gt;Describe and configure enhanced loop protection.&lt;/li&gt;&lt;li&gt;Describe and configure centrally routed bridging (CRB) EVPN-VXLAN.&lt;/li&gt;&lt;li&gt;Describe and configure edge-routed bridging (ERB) EVPN-VXLAN.&lt;/li&gt;&lt;li&gt;Describe and configure symmetric EVPN Type 2 routing.&lt;/li&gt;&lt;li&gt;Describe and configure DCI.&lt;/li&gt;&lt;li&gt;Describe and configure seamless EVPN-VXLAN stitching.&lt;/li&gt;&lt;li&gt;Describe and configure filter-based forwarding.&lt;/li&gt;&lt;li&gt;Describe enhancements to multicast functionality in an EVPN-VXLAN.&lt;/li&gt;&lt;/ul&gt;</objective><essentials>&lt;ul&gt;
&lt;li&gt;Understanding of the OSI model&lt;/li&gt;&lt;li&gt;Advanced routing knowledge&amp;mdash;the &lt;span class=&quot;cms-link-marked&quot;&gt;&lt;a class=&quot;fl-href-prod&quot; href=&quot;/swisscom/fr/course/juniper-ajer&quot;&gt;&lt;svg role=&quot;img&quot; aria-hidden=&quot;true&quot; focusable=&quot;false&quot; data-nosnippet class=&quot;cms-linkmark&quot;&gt;&lt;use xlink:href=&quot;/css/img/icnset-linkmarks.svg#linkmark&quot;&gt;&lt;/use&gt;&lt;/svg&gt;Advanced Junos Enterprise Routing &lt;span class=&quot;fl-prod-pcode&quot;&gt;(AJER)&lt;/span&gt;&lt;/a&gt;&lt;/span&gt; course or equivalent knowledge strongly recommended&lt;/li&gt;&lt;li&gt;Intermediate switching knowledge&amp;mdash;the &lt;span class=&quot;cms-link-marked&quot;&gt;&lt;a class=&quot;fl-href-prod&quot; href=&quot;/swisscom/fr/course/juniper-jex&quot;&gt;&lt;svg role=&quot;img&quot; aria-hidden=&quot;true&quot; focusable=&quot;false&quot; data-nosnippet class=&quot;cms-linkmark&quot;&gt;&lt;use xlink:href=&quot;/css/img/icnset-linkmarks.svg#linkmark&quot;&gt;&lt;/use&gt;&lt;/svg&gt;Junos Enterprise Switching &lt;span class=&quot;fl-prod-pcode&quot;&gt;(JEX)&lt;/span&gt;&lt;/a&gt;&lt;/span&gt; or equivalent knowledge&lt;/li&gt;&lt;li&gt;Intermediate to advanced Junos CLI experience&lt;/li&gt;&lt;/ul&gt;</essentials><audience>&lt;p&gt;Individuals responsible for this course includes data center implementation engineers and data center design engineers&lt;/p&gt;</audience><contents>&lt;ul&gt;
&lt;li&gt;Modern Architectures&lt;/li&gt;&lt;li&gt;IP Fabric Underlay Routing&lt;/li&gt;&lt;li&gt;IP Fabric Underlay Scaling&lt;/li&gt;&lt;li&gt;IP Fabric Underlay Configuration&lt;/li&gt;&lt;li&gt;VXLAN Overview&lt;/li&gt;&lt;li&gt;VXLAN Gateways&lt;/li&gt;&lt;li&gt;EVPN Overview&lt;/li&gt;&lt;li&gt;EVPN Protocol&lt;/li&gt;&lt;li&gt;Configuring EVPN-VXLAN Networks&lt;/li&gt;&lt;li&gt;Enhanced Ethernet Segment Loop Protection&lt;/li&gt;&lt;li&gt;Basic Data Center Architectures&lt;/li&gt;&lt;li&gt;Configuring a Collapsed Spine&lt;/li&gt;&lt;li&gt;Super Spine Configuration&lt;/li&gt;&lt;li&gt;Configuring Centrally Routed Bridging&lt;/li&gt;&lt;li&gt;Configuring Edge-Routed Bridging&lt;/li&gt;&lt;li&gt;MAC-VRF Overview&lt;/li&gt;&lt;li&gt;MAC-VRF Configuration&lt;/li&gt;&lt;li&gt;Symmetric Routing Using Type 2 EVPN&lt;/li&gt;&lt;li&gt;DCI with EVPN&amp;ndash;VXLAN Network&lt;/li&gt;&lt;li&gt;Configuring DCI&lt;/li&gt;&lt;li&gt;Seamless EVPN-VXLAN Stitching&lt;/li&gt;&lt;li&gt;Configuring Seamless EVPN-VXLAN Stitching&lt;/li&gt;&lt;li&gt;Filter-Based Forwarding&lt;/li&gt;&lt;li&gt;EVPN Multicast Extensions&lt;/li&gt;&lt;li&gt;EVPN Multicast Configuration&lt;/li&gt;&lt;li&gt;EVPN Multicast Assisted Replication&lt;/li&gt;&lt;li&gt;VXLAN Group-Based Policy&amp;mdash;Introduction&lt;/li&gt;&lt;li&gt;Zero-Touch Provisioning&lt;/li&gt;&lt;li&gt;Troubleshooting Basics&lt;/li&gt;&lt;li&gt;Data Center Devices&lt;/li&gt;&lt;/ul&gt;</contents><outline>&lt;h5&gt;Modern Architectures&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe traditional multitier architecture challenges&lt;/li&gt;&lt;li&gt;Explain next-generation data center architectures&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;IP Fabric Underlay Routing&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe what an IP fabric is&lt;/li&gt;&lt;li&gt;Explain routing in an IP fabric&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;IP Fabric Underlay Scaling&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Explain how to properly scale an IP fabric&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;IP Fabric Underlay Configuration&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Explain how to configure an OSPF-based IP fabric underlay network&lt;/li&gt;&lt;li&gt;Describe how to configure an EBGP-based IP fabric underlay network&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;Lab 1: IP Fabric&lt;/p&gt;
&lt;h5&gt;VXLAN Overview&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Explain Layer 2 connectivity over a Layer 3 network&lt;/li&gt;&lt;li&gt;Describe VXLAN Fundamentals&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;VXLAN Gateways&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe the purpose and function of VXLAN gateways&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;EVPN Overview&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe EVPN functionality&lt;/li&gt;&lt;li&gt;Describe EVPN control in a VXLAN deployment&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;EVPN Protocol&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe EVPN routing and bridging&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;Configuring EVPN-VXLAN Networks&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Discuss how to configure EVPN-controlled VXLAN&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;Lab 2: Configuring EVPN-VXLAN Networks&lt;/p&gt;
&lt;h5&gt;Enhanced Ethernet Segment Loop Protection&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe the loop potential&lt;/li&gt;&lt;li&gt;Describe and configure the ES loop-detect protocol&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;Basic Data Center Architectures&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe basic architectures and deployment scenarios&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;Configuring a Collapsed Spine&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe a collapsed spine architecture&lt;/li&gt;&lt;li&gt;Configure an underlay network&lt;/li&gt;&lt;li&gt;Configure an overlay network&lt;/li&gt;&lt;li&gt;Configure Layer 2 to Layer 3 gateways&lt;/li&gt;&lt;li&gt;Verify the VXLAN communications&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;Super Spine Configuration&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe a super spine architecture&lt;/li&gt;&lt;li&gt;Configure a super spine&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;Configuring Centrally Routed Bridging&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe EVPN-VXLAN reference architectures&lt;/li&gt;&lt;li&gt;Describe centrally routed and bridging&lt;/li&gt;&lt;li&gt;Configure centrally routed and bridging&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;Lab 3: Configure Centrally Routed Bridging&lt;/p&gt;
&lt;h5&gt;Configuring Edge-Routed Bridging&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe edge-routed bridging&lt;/li&gt;&lt;li&gt;Explain how to configure edge-routed bridging&lt;/li&gt;&lt;li&gt;Explain how to verify edge-routed bridging operations&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;Lab 4: Configuring Edge-Routed Bridging&lt;/p&gt;
&lt;h5&gt;MAC-VRF Overview&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe the benefits of deploying MAC-VRFs&lt;/li&gt;&lt;li&gt;Identify data center architectures for MAC-VRF use&lt;/li&gt;&lt;li&gt;Describe the MAC-VRF design options&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;MAC-VRF Configuration&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe the requirements of deploying MAC-VRFs&lt;/li&gt;&lt;li&gt;Describe the MAC-VRF use case&lt;/li&gt;&lt;li&gt;Configure common parameters&lt;/li&gt;&lt;li&gt;Configure a VLAN-based MAC-VRF&lt;/li&gt;&lt;li&gt;Configure a VLAN-aware MAC-VRF&lt;/li&gt;&lt;li&gt;Configure a VLAN-bundle MAC-VRF&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;Lab 5: MAC-VRF Configuration&lt;/p&gt;
&lt;h5&gt;Symmetric Routing Using Type 2 EVPN&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe asymmetric routing&lt;/li&gt;&lt;li&gt;Describe symmetric routing&lt;/li&gt;&lt;li&gt;Implement symmetric routing&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;Lab 6: Symmetric Routing Configuration&lt;/p&gt;
&lt;h5&gt;DCI with EVPN&amp;ndash;VXLAN Network&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Discuss DCI with EVPN-VXLAN Network&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;Configuring DCI&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Discuss how to configure DCI in the data center&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;Lab 7: Data Center Interconnect&lt;/p&gt;
&lt;h5&gt;Seamless EVPN-VXLAN Stitching&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Explain the purpose of seamless EVPN-VXLAN stitching&lt;/li&gt;&lt;li&gt;Discuss seamless EVPN-VXLAN design options&lt;/li&gt;&lt;li&gt;Describe a packet walkthrough for seamless EVPN-VXLAN stitching&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;Configuring Seamless EVPN-VXLAN Stitching&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Explain how to configure seamless EVPN-VXLAN stitching&lt;/li&gt;&lt;li&gt;Describe how to verify EVPN-VXLAN stitching operations&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;Lab 8: Implementing Seamless EVPN-VXLAN Stitching&lt;/p&gt;
&lt;h5&gt;Filter-Based Forwarding&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Discuss the purpose of filter-based forwarding in a data center&lt;/li&gt;&lt;li&gt;Explain how to configure filter-based forwarding in a data center&lt;/li&gt;&lt;li&gt;Describe how to verify filter-based forwarding in a data center&lt;/li&gt;&lt;/ul&gt;&lt;p&gt;Lab 9: Implementing Filter-Based Forwarding&lt;/p&gt;
&lt;h5&gt;EVPN Multicast Extensions&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe the multicast extensions to EVPN&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;EVPN Multicast Configuration&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Explain how to configure EVPN multicast&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;EVPN Multicast Assisted Replication&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe the potential problem with EVPN multicast&lt;/li&gt;&lt;li&gt;Illustrate a use case&lt;/li&gt;&lt;li&gt;Describe assisted replication&lt;/li&gt;&lt;li&gt;Configure assisted replication&lt;/li&gt;&lt;li&gt;Describe assisted replication with SMET&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;VXLAN Group-Based Policy&amp;mdash;Introduction&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe an overview of VXLAN group-based policies&lt;/li&gt;&lt;li&gt;Describe the benefits of VXLAN group-based policies&lt;/li&gt;&lt;li&gt;Configure a VXLAN group-based policy filter&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;Zero-Touch Provisioning&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Explain zero-touch provisioning&lt;/li&gt;&lt;li&gt;Configure a QFX5100 Series switch using ZTP&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;Troubleshooting Basics&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe troubleshooting tools&lt;/li&gt;&lt;li&gt;Explain a basic troubleshooting approach&lt;/li&gt;&lt;/ul&gt;&lt;h5&gt;Data Center Devices&lt;/h5&gt;&lt;ul&gt;
&lt;li&gt;Describe fixed format platforms&lt;/li&gt;&lt;li&gt;Describe modular platforms&lt;/li&gt;&lt;li&gt;Describe virtual platforms&lt;/li&gt;&lt;/ul&gt;</outline><objective_plain>- Describe basic and advanced data center design concepts.
- Describe and configure an IP fabric.
- Describe and configure an EVPN-VXLAN data center.
- Describe and configure enhanced loop protection.
- Describe and configure centrally routed bridging (CRB) EVPN-VXLAN.
- Describe and configure edge-routed bridging (ERB) EVPN-VXLAN.
- Describe and configure symmetric EVPN Type 2 routing.
- Describe and configure DCI.
- Describe and configure seamless EVPN-VXLAN stitching.
- Describe and configure filter-based forwarding.
- Describe enhancements to multicast functionality in an EVPN-VXLAN.</objective_plain><essentials_plain>- Understanding of the OSI model
- Advanced routing knowledge—the Advanced Junos Enterprise Routing (AJER) course or equivalent knowledge strongly recommended
- Intermediate switching knowledge—the Junos Enterprise Switching (JEX) or equivalent knowledge
- Intermediate to advanced Junos CLI experience</essentials_plain><audience_plain>Individuals responsible for this course includes data center implementation engineers and data center design engineers</audience_plain><contents_plain>- Modern Architectures
- IP Fabric Underlay Routing
- IP Fabric Underlay Scaling
- IP Fabric Underlay Configuration
- VXLAN Overview
- VXLAN Gateways
- EVPN Overview
- EVPN Protocol
- Configuring EVPN-VXLAN Networks
- Enhanced Ethernet Segment Loop Protection
- Basic Data Center Architectures
- Configuring a Collapsed Spine
- Super Spine Configuration
- Configuring Centrally Routed Bridging
- Configuring Edge-Routed Bridging
- MAC-VRF Overview
- MAC-VRF Configuration
- Symmetric Routing Using Type 2 EVPN
- DCI with EVPN–VXLAN Network
- Configuring DCI
- Seamless EVPN-VXLAN Stitching
- Configuring Seamless EVPN-VXLAN Stitching
- Filter-Based Forwarding
- EVPN Multicast Extensions
- EVPN Multicast Configuration
- EVPN Multicast Assisted Replication
- VXLAN Group-Based Policy—Introduction
- Zero-Touch Provisioning
- Troubleshooting Basics
- Data Center Devices</contents_plain><outline_plain>Modern Architectures


- Describe traditional multitier architecture challenges
- Explain next-generation data center architectures
IP Fabric Underlay Routing


- Describe what an IP fabric is
- Explain routing in an IP fabric
IP Fabric Underlay Scaling


- Explain how to properly scale an IP fabric
IP Fabric Underlay Configuration


- Explain how to configure an OSPF-based IP fabric underlay network
- Describe how to configure an EBGP-based IP fabric underlay network
Lab 1: IP Fabric

VXLAN Overview


- Explain Layer 2 connectivity over a Layer 3 network
- Describe VXLAN Fundamentals
VXLAN Gateways


- Describe the purpose and function of VXLAN gateways
EVPN Overview


- Describe EVPN functionality
- Describe EVPN control in a VXLAN deployment
EVPN Protocol


- Describe EVPN routing and bridging
Configuring EVPN-VXLAN Networks


- Discuss how to configure EVPN-controlled VXLAN
Lab 2: Configuring EVPN-VXLAN Networks

Enhanced Ethernet Segment Loop Protection


- Describe the loop potential
- Describe and configure the ES loop-detect protocol
Basic Data Center Architectures


- Describe basic architectures and deployment scenarios
Configuring a Collapsed Spine


- Describe a collapsed spine architecture
- Configure an underlay network
- Configure an overlay network
- Configure Layer 2 to Layer 3 gateways
- Verify the VXLAN communications
Super Spine Configuration


- Describe a super spine architecture
- Configure a super spine
Configuring Centrally Routed Bridging


- Describe EVPN-VXLAN reference architectures
- Describe centrally routed and bridging
- Configure centrally routed and bridging
Lab 3: Configure Centrally Routed Bridging

Configuring Edge-Routed Bridging


- Describe edge-routed bridging
- Explain how to configure edge-routed bridging
- Explain how to verify edge-routed bridging operations
Lab 4: Configuring Edge-Routed Bridging

MAC-VRF Overview


- Describe the benefits of deploying MAC-VRFs
- Identify data center architectures for MAC-VRF use
- Describe the MAC-VRF design options
MAC-VRF Configuration


- Describe the requirements of deploying MAC-VRFs
- Describe the MAC-VRF use case
- Configure common parameters
- Configure a VLAN-based MAC-VRF
- Configure a VLAN-aware MAC-VRF
- Configure a VLAN-bundle MAC-VRF
Lab 5: MAC-VRF Configuration

Symmetric Routing Using Type 2 EVPN


- Describe asymmetric routing
- Describe symmetric routing
- Implement symmetric routing
Lab 6: Symmetric Routing Configuration

DCI with EVPN–VXLAN Network


- Discuss DCI with EVPN-VXLAN Network
Configuring DCI


- Discuss how to configure DCI in the data center
Lab 7: Data Center Interconnect

Seamless EVPN-VXLAN Stitching


- Explain the purpose of seamless EVPN-VXLAN stitching
- Discuss seamless EVPN-VXLAN design options
- Describe a packet walkthrough for seamless EVPN-VXLAN stitching
Configuring Seamless EVPN-VXLAN Stitching


- Explain how to configure seamless EVPN-VXLAN stitching
- Describe how to verify EVPN-VXLAN stitching operations
Lab 8: Implementing Seamless EVPN-VXLAN Stitching

Filter-Based Forwarding


- Discuss the purpose of filter-based forwarding in a data center
- Explain how to configure filter-based forwarding in a data center
- Describe how to verify filter-based forwarding in a data center
Lab 9: Implementing Filter-Based Forwarding

EVPN Multicast Extensions


- Describe the multicast extensions to EVPN
EVPN Multicast Configuration


- Explain how to configure EVPN multicast
EVPN Multicast Assisted Replication


- Describe the potential problem with EVPN multicast
- Illustrate a use case
- Describe assisted replication
- Configure assisted replication
- Describe assisted replication with SMET
VXLAN Group-Based Policy—Introduction


- Describe an overview of VXLAN group-based policies
- Describe the benefits of VXLAN group-based policies
- Configure a VXLAN group-based policy filter
Zero-Touch Provisioning


- Explain zero-touch provisioning
- Configure a QFX5100 Series switch using ZTP
Troubleshooting Basics


- Describe troubleshooting tools
- Explain a basic troubleshooting approach
Data Center Devices


- Describe fixed format platforms
- Describe modular platforms
- Describe virtual platforms</outline_plain><duration unit="d" days="5">5 jours</duration><pricelist><price country="DE" currency="USD">5000.00</price><price country="AT" currency="USD">5000.00</price><price country="CH" currency="USD">5000.00</price><price country="SE" currency="USD">5000.00</price><price country="IL" currency="USD">5000.00</price><price country="AE" currency="USD">5000.00</price><price country="SI" currency="USD">5000.00</price><price country="SK" currency="USD">5000.00</price></pricelist><miles/></course>